Comprehensive arthroscopy training simulator with unmatched realism: real graphics, real instruments, real feel. Prepare for the operating room with precision and confidence using our state-of-the-art mixed reality technology.
VirtaMed ArthroS™ Ergonomic Orthopedic Platform
- VirtaMed simulation platform with electromagnetic tracking
- VirtaMed software framework
- High-end PC with adjustable 27” multi touch screen
- Movable and height adjustable VirtaMed simulation platform
Includes original instruments adapted for simulation:
- 1 Arthroscope
- 1 Probe / hook
- 1 Grasper / punch
- 1 Arthroscopic shaver
Features:
- High-fidelity simulation
- Tactile sensation
- Ambidextrous training
- SimProctor™ best practice training
- Objective feedback
- Customizable proficiency courses
- Multi-lingual support
- Rapid switch between modules
VirtaMed ArthroS™ Orthopedic Platform Extension
- Extension to an existing non-ArthroS™ VirtaMed platform
- Electromagnetic tracking update to enable all orthopedic modules
- Transport case for easy moving and storage
Includes original instruments adapted for simulation:
- 1 Arthroscope
- 1 Probe / hook
- 1 Grasper / punch
- 1 Arthroscopic shaver
Features:
- High-fidelity simulation
- Tactile sensation
- Ambidextrous training
- SimProctor™ best practice training
- Objective feedback
- Customizable proficiency courses
- Multi-lingual support
VirtaMed ArthroS™ FAST Module
- 8 cases with a total of 136 exercises for camera navigation: Image centering, horizon control & periscoping, following an object
- 8 cases with a total of 164 exercises for bimanual skills: triangulation and grasping
- Exercises include training of ambidextrous skills, posterior and anterior access, horizontal and vertical horizon control, use of 0°, 30° and 70° arthroscope
Includes:
- 1 ArthroS™ FAST stand adapted from the original Sawbones model
VirtaMed ArthroS™ Knee Module
- 14 cases for basic skills training: guided diagnostics, triangulation, and therapeutic arthroscopies
- 19 cases for diagnostic arthroscopy: different meniscus lesions, unhappy triad, arthrosis grade I-IV, synovitis
- 11 cases for therapeutic arthroscopy: different meniscus lesions, synovitial membrane inflammations, loose body removal
- Compatible with VirtaMed ArthroS™ ACL Reconstruction
Includes:
- 1 anatomic right knee model; allows for physical manipulation of the joint, including varus and valgus, flexion, and extension
- Choice of skin tones available
VirtaMed ArthroS™ ACL Reconstruction Module
- Add-on module to VirtaMed ArthroS™ Knee
- 1 case to evaluate the effects of incorrect femoral and tibial tunnel placements on the resulting graft position
- 2 practice cases for femoral and tibial tunnel placement
- 3 master cases composed of full-length procedures for an acute ACL tear, a partial ACL tear and a chronic ACL tear
Includes:
- 1 multihandle instrument to replicate a scalpel, guide pin, reamer, tibial drill guide, guide wire, interference screw inserter
VirtaMed ArthroS™ Meniscal Repair Module
- Add-on module to VirtaMed ArthroS™ Knee
- 4 cases all-inside technique: medial peripheral tear and lateral radial tear
- 2 cases outside-in technique: medial peripheral tear
- 2 cases for medial meniscus root tear repair using a transtibial two-tunnel pull-out technique
- 2 cases for medial meniscus ramp lesion repair using a two- portal posteromedial approach
Includes:
- 1 multihandle instrument to replicate a scalpel, tibial drill guide, reamer, needle inserter, suture passer
VirtaMed ArthroS™ AANA Meniscectomy Module
- Add-on module to VirtaMed ArthroS™ Knee
- 5 guided cases with various meniscus tears, highlighting the optimal regions for resection
- 5 therapeutic cases with various meniscus tears
- Scored using Copernicus metrics developed by the Arthroscopy Association of North America (AANA)
VirtaMed ArthroS™ Shoulder Module
- 12 cases with a total of 18 exercises for basic skills training: guided diagnostic cases, triangulation cases
- 14 cases for diagnostic arthroscopy: healthy anatomy, lesions in rotator cuff, labral tears, impingement syndrome
- 3 cases for therapeutic arthroscopy: subacromial decompression and debridement, loose body removal
- Compatible with VirtaMed ArthroS™ Rotator Cuff Repair Module
Includes:
- 1 anatomic right shoulder model with magnetic tracking; allows for realistic palpation of landmarks, and movements including abduction, adduction, flexion, traction, rotation
- Free choice of portals for portal placement training
- Rapid switch between lateral decubitus and beach chair position
VirtaMed ArthroS™ Rotator Cuff Repair Module
- Add-on Module to ArthroS™ Shoulder
- 3 diagnostic patient cases with different rotator cuff tears (Crescent and L-Shaped supraspinatus tears)
- Simulated procedure: double-row rotator cuff repair, including correct anchor locations, placement, knotless suture management, tendon piercing, and fixation procedure steps
- 6 Practice cases for diagnostics and preparation of tear, medial and lateral row anchor placement
- 3 master cases composed of full-length procedure
- 3D cross-sectional view showing anchor placement in the humerus
Includes:
- 1 multitool instrument to replicate a threaded dilator, awl, and anchor implant system
VirtaMed ArthroS™ Hip Module
- Access training using virtual fluoroscopy
- 16 cases for basic skills training in central and peripheral compartments: guided diagnostics and triangulation
- 4 cases for diagnostic arthroscopy: healthy anatomy, labral tear, femoroacetabular impingement, cartilage flaps
- 2 cases for therapeutic arthroscopy: loose body removal, impingement decompression
Includes:
- 1 anatomic hip model with magnetic tracking; allows for realistic palpation of bony landmarks, joint traction, hip flexion and femur rotation
- Rapid switch between lateral and supine position
- 1 adapted guidewire
- 1 halfpipe for portal placement
- 1 skin insert with portals
- 2 replaceable skin inserts without portals
VirtaMed ArthroS™ Ankle Module
6 cases for basic skills training: guided diagnostic cases, triangulation cases
▪ 6 cases for basic skills training: guided diagnostic cases, triangulation cases
▪ 5 cases for diagnostic arthroscopy: healthy anatomy, cartilage defects, loose bodies and impingement conditions
▪ 2 cases for therapeutic arthroscopy: loose body removal, impingement decompression
Includes:
▪ 1 anatomic left ankle model with magnetic tracking; allows for realistic palpation of bony landmarks, joint traction, flexion, abduction, adduction, inversion and eversion
▪ Rapid switch between prone and supine position